Solution 3000 – RF Diagnose

On IUI-SOL-TEXT codepad, we can type in [1][4] to do RF Diagnose.

For example, the two numbers 95/89 in the brackets, 95 is Signal Level and 89 is Signal Margin.

Signal Level 

This parameter indicates the relative strength of the signal.  The measurement returned is a value ranging from 0 – 99 with each digit encoded as a BCD (Binary-Coded Decimal).

Bit 8Bit 7Bit 6Bit 5Bit 4Bit 3Bit 2Bit 1
10’s Digit1’s Digit

Note:    The higher the value the stronger the signal.

Signal Margin 

This parameter represents a relative measurement of the amount of signal level above the noise floor.  The measurement returned is a value ranging from 0 – 99 with each digit encoded as a BCD.

Bit 8Bit 7Bit 6Bit 5Bit 4Bit 3Bit 2Bit 1
10’s Digit1’s Digit

Note:    The higher the value number, the greater the signal margin. 